
Every metal rack a data center needs from a fabricator: battery racks for UPS and BESS rooms, equipment and cable racks for the electrical room, server rack frames and containment for the hall, rack enclosures and cages, and CDU and cooling-equipment frames — built to print, welded or knock-down, powder-coated in-house and delivered at campus scale.
Racks and frames are the steel that data center equipment actually lives in: battery strings in the UPS room, cable and busway drops in the electrical room, coolant distribution units and pumps on the mechanical side, servers and network gear in the hall, and the cages and containment that separate one tenant or one row from the next. They are ordered by the hundreds per campus, they have to arrive on the equipment's schedule, and they have to be identical.
FabTek fabricates racks, frames and rack enclosures to print at our Hazlehurst, Mississippi plants — welded carbon steel and aluminum, or bolted knock-down for shipping density, laser-cut and CNC-formed for repeatable hole patterns, powder-coated in-house, and delivered wrapped and sequenced to the site. Server rack frames are built to EIA-310 rail spacing and 19" or 23" widths where specified. We build the steel; the equipment, the listings and the seismic engineering stay with the equipment OEM and the engineer of record.
Open racks and stands for UPS and BESS battery strings, with seismic bracing details per the engineer of record.
Frames for busway drops, cable management, static transfer switches, monitoring gear and network distribution in the electrical room.
Welded rack frames and rail structures to EIA-310 dimensions, hot/cold-aisle containment frames, tenant cages and partition frames.
Sheet-metal enclosures around rack rows or equipment groups, CDU and pump frames, and mounting frames for cooling distribution.







Hyperscale and colocation data centers — new campus builds ordering racks by the hundreds, and expansions retrofitting electrical rooms and halls. Our equipment skids and platforms page covers the neighboring structural steel, and our guide to PDU, UPS and battery cabinets covers the enclosed equipment the racks sit beside.
| Materials | Carbon steel (HR/CR), aluminum 5052; stainless hardware |
|---|---|
| Construction | Welded frames for rigidity, or bolted knock-down for shipping density — customer's choice |
| Tolerances | Hole patterns laser-cut for repeatability across an order; EIA-310 rail spacing and 19"/23" widths where specified |
| Finish | In-house powder coat, black or specified RAL; galvanized on request |
| Welding | AWS D1.1 / D1.3 |
| Load / seismic | Fabricated to the design and anchorage details of the engineer of record |
| Delivery | Campus-scale orders staged and sequenced to the equipment delivery schedule |
| Also specified as | Battery rack, equipment rack, cable rack, rack frame, server rack frame, rack enclosure, containment frame, tenant cage, CDU frame, data center steel racks |
Representative capabilities — exact ranges, ratings, and finishes are confirmed per project. Send drawings for a firm quote.
The rack order for a campus is a production program, not a job: the same frame, hundreds of times, arriving in the sequence the rooms energize. FabTek runs it that way — first article against your inspection plan, fixtures locked, releases against the site schedule — on the same dedicated-line model we use for transformer cabinets.
Built at four production sites in Hazlehurst, Mississippi.
ISO 9001:2015 quality management, AWS-certified welding, OSHA-compliant facilities.
In-house powder coat backed by an IEEE 2000-hour salt-spray certification.
Reserved-line capacity and the automation to grow with your volume.
Yes — battery racks, equipment and cable racks, server rack frames, containment and cages, rack enclosures and CDU frames, fabricated to print and powder-coated in-house at our Hazlehurst, Mississippi plants.
FabTek fabricates the racks, frames, skids and enclosures for data center power, cooling and white-space infrastructure as one domestic source, with campus-scale sequenced delivery.
Yes — server rack frames and rails to EIA-310 spacing in 19" and 23" widths, or to your custom print.
Either — welded frames for rigidity or bolted knock-down for shipping density, to your preference.
Explore related lines: Data center steel · Equipment skids & platforms · Bus duct housings · Data center fabrication
Further reading: PDU, UPS & battery cabinets for data centers · Inside the electrical room · Cable tray supports & ladder rack






Send the rack drawings and the campus quantity — we'll quote a first article and a sequenced production release.