Certified welders across MIG, TIG, laser and stud welding cells — structural steel to AWS D1.1, sheet metal to D1.3, stainless to D1.6 — for transformer tanks, cabinets, bus duct, substation structures and everything else FabTek builds.
Power-system fabrication spans three welding worlds. A substation dead-end structure is heavy structural steel welded to AWS D1.1. A transformer cabinet is thin sheet welded to D1.3 with a finish that will show every defect after powder coat. A 4X stainless enclosure or a sanitary conveyor is welded to D1.6 with ground and polished seams. A transformer tank has to hold oil under vacuum. Most shops are qualified for one of those; FabTek's welding cells are qualified for all of them, because the products we build require all of them.
The department is organized as cells — structural welding with positioners and manipulators for heavy weldments, sheet-metal cells for cabinets and enclosures, a stainless cell kept clean of carbon contamination, a laser welding cell for thin material and long seams, and stud welding for hardware — with certified welders, written weld procedures and documented inspection under our ISO 9001:2015 system. Every weldment carries the welder ID and inspection record for the customer's file.
Structural steel, sheet metal, stainless and aluminum welded to AWS D1.1, D1.3 and D1.6 with certified welders and written procedures.
Thin sheet and long seams welded with minimal heat input and distortion for cabinets, enclosures and stainless work.
Threaded studs, pins and insulation studs applied to cabinets, tanks and panels without through-holes.
Leak-tight tank bodies, covers and conservators welded and pressure or vacuum tested.
Dead-end structures, poles, stands, skids and platforms welded on positioners for full-penetration joints.
Continuous, ground and polished welds for 4X enclosures and washdown conveyors.

Parts tacked to the detail with weld maps on the fixture.

MIG, TIG, laser and stud welding by certified welders to AWS D1.1, D1.3 and D1.6.

Visual and dimensional checks with the records the code and the customer require.

Weldments move to the blast room and powder coat line on the same floor.

Transformer tanks and covers, substation structures and tubular poles, switchgear and control enclosures, bus duct and busway housings, sanitary conveyors and equipment skids and platforms. Welding-only work — weldments to a customer's drawings and procedures — is quoted as well.
| Codes | AWS D1.1 (structural steel), D1.3 (sheet steel), D1.6 (stainless); customer procedures on request |
|---|---|
| Processes | GMAW (MIG), GTAW (TIG), laser welding, stud welding (Arc 1200); SMAW and FCAW where specified |
| Equipment | Miller and Airgas Deltaweld MIG cells, laser welding cell, stud welder, positioners and manipulators, weld cleaners |
| Materials | Carbon steel, galvanized and galvanneal, stainless, aluminum |
| Testing | Visual and dimensional inspection; pressure and vacuum leak testing on tanks; NDT through partners where specified |
| Documentation | Welder qualifications, WPS/PQR, inspection records by weldment; ISO 9001:2015 |
| Also specified as | Welding services, certified welding, AWS D1.1 welding, MIG welding services, TIG welding services, stainless welding, structural welding, contract welding |
Representative capabilities — exact ranges, ratings, and finishes are confirmed per project. Send drawings for a firm quote.
Keeping structural, sheet-metal and stainless welding under one roof is only useful if each is done right, and that means separating them. FabTek runs a stainless cell with its own tooling and abrasives so carbon contamination never reaches a 4X enclosure; runs structural welding on positioners so a full-penetration joint is welded in position rather than overhead; and runs sheet-metal cells with the fixtures and heat control that keep a cabinet door flat. Our spec sheet on which welding code applies explains how the three differ, and ISO 9001 and AWS-certified welds covers the documentation.

Built at four production sites in Hazlehurst, Mississippi.
ISO 9001:2015 quality management, AWS-certified welding, OSHA-compliant facilities.
In-house powder coat backed by an IEEE 2000-hour salt-spray certification.
Reserved-line capacity and the automation to grow with your volume.
Welders are qualified to AWS D1.1 for structural steel, D1.3 for sheet steel and D1.6 for stainless, with written procedures and documented inspection under ISO 9001:2015.
FabTek Industries welds structural steel, sheet metal, stainless and aluminum in dedicated cells at its Hazlehurst plants, with cutting, forming and powder coat on the same site.
Yes. Transformer tank bodies, covers and conservators are pressure or vacuum tested per the drawing and shipped with the test record.
Yes. Weldments to your drawings and procedures are quoted and documented the same way as our own products.
Explore related lines: Transformer tanks · Substation structures · Switchgear enclosures · Sanitary conveyors
Further reading: AWS D1.1 vs D1.3 vs D1.6 · ISO 9001 and AWS-certified welds · Welded vs. bolted transformer tanks






Have weldments to quote? Send the drawings and the code — we'll come back with a plan and a firm price, typically within one business day.